Rice-lake 880 Performance Series Indicator/Controller Techni Bedienungsanleitung Seite 32

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 120
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 31
26 880 Technical/Service Manual
3.0 Configuration
To configure the 880 indicator, the indicator must be placed in setup mode. The setup switch is accessed through a
small hole on the enclosure backplate, insert a non-conductive tool into the access hole and press the configuration
switch. Indicator display changes to show
SCALE.
Note
Important
Use caution when inserting the non-conductive tool into the backplate, press the tool in about 3/4 inch,
using the board as a guide, until the switch
is engaged. Do not use excessive force that may damage the
switch.
If the audit trail is enabled, setup mode may be accessed by pressing
MENU
. Press or until SETUP is
displayed, then press
to SCALE. See Section 2.9.
.
J1 J2 J3 J4 J5 J6
Setup Switch Access
Figure 3-1. Back View – Setup Switch Access
When the indicator is placed in setup mode, the word SCALE is shown on the display. The SCALE menu is the first
of eight top-level menus used for configuring the indicator. Detailed descriptions of these menus are given in
Section 3.2.
When configuration is complete, press
MENU
to return to the weigh mode.
3.1 Configuration Methods
The 880 indicator can be configured by using the front panel keys to navigate through a series of configuration
menus or by sending commands or configuration data to any communication port. Configuration using the menus
is described in Section 3.1.3.
Configuration using the communication port can be accompli
shed using either the EDP command set described in
Section 6.0 or Version 3.0 or later of the Revolut
ion configuration utility.
3.1.1 Revolution Configuration
The Revolution configuration utility provides the preferred method for configuring the 880 indicator. Revolution
runs on a personal computer to set configuration parameters for the indicator (see Section 5.0). When Revolution
configuration is complete, configuration data is downloaded to the indicator
.
3.1.2 EDP Command Configuration
The EDP command set can be used to configure the 880 indicator using either a personal computer or terminal.
Like Revolution, EDP command configuration sends commands to the indicator remote EDP port; unlike
Revolution, EDP commands can be sent using any external device capable of sending ASCII characters over a
serial connection.
EDP commands duplicate the functions availab
le using the indicator front panel and provide some functions not
otherwise available. EDP commands can be used to simulate pressing front panel keys, to configure the indicator,
or to dump lists of parameter settings. See Section 6.0 for more information about using the EDP command set.
Seitenansicht 31
1 2 ... 27 28 29 30 31 32 33 34 35 36 37 ... 119 120

Kommentare zu diesen Handbüchern

Keine Kommentare